Monday, July 30, 2018

Auro OtoSys IM100 adds Spare Key BMW FEM F30 2012

How-to: Add spare keys to BMW FEM/BDC F30 diesel year 2012 using Auro OtoSys IM100/IM600 tablet on the bench.
Note: Both IM100/IM600 has BMW FEM/BDC capability. IM600 is capable of BMW CAS4 and Mercedes-Benz key programming, while IM100 does not. If you are interested in IM600, please contact:
Whatsapp : +86 18259252285
Skype: obdii365.com
E-Mail:sales@obdii365.com


Main Steps:
Check key status
Backup EEPROM data
Learn Key

Procedure:


Step 1: Check key status 
Disassemble FEM/BDC module
Connect with FEM module, IM100 and UP200 programmer
Select IMMO function->BMW->System selection->FEM/BDC immobilizer
auro-im100-bmw-f30-fem-1
auro-im100-bmw-f30-fem-2
Make sure the engine is off
auro-im100-bmw-f30-fem-3
Check Key Status
auro-im100-bmw-f30-fem-4
Put the tested key/working key into induction antenna
auro-im100-bmw-f30-fem-5
Put another keys into induction antenna one by one to check key status. New keys are not locked

Step 2: Backup EEPROM
Back to BMW menu, select Smart Mode
Auro IM100 detect current immobilizer system is FEM/BDC
Reading vehicle information and ecu information
Backing up coding files
Going to modify EEPROM data automatically:
1. Please disassemble the EEPROM chip and connect the programmer
2. The FEM module is chip M9S128 and the BDC module is chip M95256
3. If you operate the EEPROM with clamp, you should turn off the +12V power first!
auro-im100-bmw-f30-fem-6
Backup EEPROM data automatiocally
Automatically modified EEPROM data successfully
The backup path is /mint/sdcard/scan/UserData/autobackup/
EEPROM chip operated successfully! Please install the chip back to the ECU module

Step 3: Learn Key
auro-im100-bmw-f30-fem-7
Notice:
The programming is about to start, make sure the supply voltage exceeds 13V and is stable.
1.Please make sure that the vehicle power is ok
2.Please make sute that the OBD diagnostic cable is correctly connected
3. Please make sure that the power icon on the top right corner of the Auro im100 diagnostic tool correctly displays the voltage.
auro-im100-bmw-f30-fem-8
Programming key in procedure
auro-im100-bmw-f30-fem-9
Going to restore  EEPROM data automatically:
1. Please disassemble the EEPROM chip and connect the programmer
2. The FEM module is chip M9S128 and the BDC module is chip M95256
3. If you operate the EEPROM with clamp, you should turn off the +12V power first!
Restoring EEPROM data automatically
EEPROM chip operated successfully. Install the chip back to ECU module
auro-im100-bmw-f30-fem-10
The restoration coding file is about to start
1.Please make sure that the vehicle power is ok
2.Please make sute that the OBD diagnostic cable is correctly connected
3. Please make sure that the power icon on the top right corner of the diagnostic tool
correctly displays the voltage.
Restore coding data files.
auro-im100-bmw-f30-fem-11
Note:
1.Before the key can be written and cleared, the password must be read out first.
2.Before the key can be written or cleared, the corresponding key position must be selected first.

Do you have a working key? Yes.
Insert working key into emergency start coil, select Read password
auro-im100-bmw-f30-fem-12
Read password, DME, ISN code success
auro-im100-bmw-f30-fem-13
Insert a new key into induction coil, select a key position and press Write Key
auro-im100-bmw-f30-fem-14
Key learning has 4 steps,
The first step of authenticating key information is in progress
The seconds steps if writing data into key is in progress
The third step of resetting ecu is in progress
The fourth step of verifying key information is in progress
auro-im100-bmw-f30-fem-15
Write key success.
Put the key close to start induction coil, press and hold the ingnition for 10s.
After key learning is completed, the key can be normally used.
auro-im100-bmw-f30-fem-16
You can program next key with Auro OtoSys IM100
Notice:
When the number of keys is greater than three, the newly added keys may have no remote control function
due to the imitation of BMW system.